District heating, direct heating/ mixed circuit
|
• |
Demand based control of remote energy transfer stations after target value request of downstream control circuits |
• |
Outdoor temperature-compensated flow temperature control for radiators and convectors and low temperature heating circuits with mixer |
|
|
Unmixed heating |
1 circuit |
Mixed heating |
1 circuit |
District heating |
1 valve |
![appl-smile-0506ge51](images/produkty/appl-smile-0506ge51colres.jpg) |
Functions |
• |
The basic functions are contained in an indestructible program. |
• |
All the parameters are predefined with sensible basic settings and allow individual adjustments as necessary. PCs are not required for this. |
• |
All the relay outputs can be tested manually. |
|
Remote energy control |
• |
Functions according to AGFW guidelines |
• |
Demand control of setpoint request from downstream control circuits |
• |
Sliding or fixed maximum limitation of the remote energy return temperature |
• |
Minimum valve stroke for exact recording of heat volume in low-load operation |
• |
Interval rinse for temperature recording in the primary return with closed remote energy valve |
|
Heating circuit |
• |
Time switch for daily, weekly and holiday programs for each heating circuit |
• |
Minimum/maximum limit of flow temperature |
• |
Frost protection function |
• |
Optimisation of switch-on times |
• |
Pump switching on demand |
• |
Forced pump running |
• |
Max. limitation of the heating circuit return temperature (only for heating circuit with mixer) |
|
Combination |
• |
Combination option of up to five freely-selectable SMILE controllers |
|
Communication |
• |
Communication takes place over the system bus without additional interfaces |
• |
Distance (max. 100 m) |
• |
Remote operation with the wall modules SDW.. also takes place using the system bus |
|
Fault message |
• |
If the required temperatures cannot be achieved within a reasonable time, or sensors interrupt or short-out, then the controller will generate a fault message. |
|
Description | Additional Product Type |
With connection base for wall installation | SDC7-21WM |
With connectable terminal strips for control panel installation | SDC7-21PM |
Description | Additional Product Type |
Outside air temperature sensor | AF20 |
Contact temperature sensor WF, VFB (2) | VF20A |
Description | Additional Product Type |
Remote control with temperature selector/sensor and mode switch | SDW10WE |
Return temperature sensor RLF | VF20A |
Description | Additional Product Type |
Immersion temperature sensor (instead of VF20A) | VF20T |
Easy-to-use remote operation with display and complete programming unit along with temperature sensor/selector (instead of SDW10) | SDW30 |
Base for Smile Controller, for control panel installation as touch protection | SCS-12 |
Connecting base for wall installation of SMILE panel models | SWS-12 |
Reducing attachment frame for control panel installation, assuming available control panel cut-out on controllers
ZG52 /53 /55 / 82 /85 or
ZG215 /215V /252 /254 | SRR |
Description | Additional Product Type |
Safety limiting thermostat STW | STW+TR |