Thermostatic mixing valve with scald protection, TM50

Thermostatic mixing valve with scald protection, TM50
TM50 thermostatic mixing valves provide control of the water temperature and are used: - For centralised control on hot water supply units or for localised control adjacent to point-use outlets. Or for use with solar-heated hot water units with dual energy source. - In heating systems with underfloor heating or for limiting boiler return temperatures. Where a system includes a hot water circulation circuit, a KB191 return flow retarder unit (see accessories) must be fitted to prevent cold water backfeeding and cooling the mixed water at the outlets.
Media Water
Body material brass, dezincification resistant
Port connection type external threads
Max. media temperature 90 oC
Temp. setpoint range 30 ... 60 oC
Additional description
Highly sensitive thermal element with good all-round water temperature sensing, even at low flow rates
Simple setting of the required water temperature
Scald protection - the hot water inlet is automatically cut off if the cold supply fails provided that the hot water inlet temperature is at least 10 K higher than that of mixed water setting
The cold water inlet is automatically cut off if the hot supply fails
Inner components are of scale-resistant materials
applcertmarkghostge23
With male connections
Type
TM50-1/2E  PDF
Accessories
DescriptionAdditional Product Type
Return flow-retarder unit for fitting to systems which include a hot water circulation circuit - to prevent cold water backfeeding and cooling the mixed water at the outletsKB191-3/4