Inverters 1,1..30kW, IP21/IP54, NXL HVAC

Inverters 1,1..30kW, IP21/IP54, NXL HVAC
Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features
the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series NXL HVAC
RFI-filter integrated
Brake chopper integrated
Input phase 3
Rated voltage 380..500V (400V)
Output frequency 0 ... 320 Hz
Frequency resolution 0.01 Hz
Serial communication Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity fulfills all EMC immunity requirements
Emissions EN61800-3 (2004)
Safety EN50178, EN60204-1, EN60950, IEC61800-5, CE, FI, GOST R
IP21
Protection classLow overload (for Fan/Pump)Low overload IcontHigh overload (for Machines)High overload IcontType
 kWAkWA 
IP211.13.30.752.2HVAC03C2  PDF
IP211.54.31.13.3HVAC04C2  PDF
IP212.25.61.54.3HVAC05C2  PDF
IP2137.62.25.6HVAC07C2  PDF
IP214937.6HVAC09C2  PDF
IP215.51249HVAC12C2  PDF
IP217.5165.512HVAC16C2  PDF
IP2111237.516HVAC23C2  PDF
IP2115311123HVAC31C2  PDF
IP2118.5381531HVAC38C2  PDF
IP21224618.538HVAC46C2  PDF
IP2130612246HVAC61C2  PDF
IP54
Protection classLow overload (for Fan/Pump)Low overload IcontHigh overload (for Machines)High overload IcontType
 kWAkWA 
IP541.13.30.752.2HVAC03C5  PDF
IP541.54.31.13.3HVAC04C5  PDF
IP542.25.61.54.3HVAC05C5  PDF
IP5437.62.25.6HVAC07C5  PDF
IP544937.6HVAC09C5  PDF
IP545.51249HVAC12C5  PDF
IP547.5165.512HVAC16C5  PDF
IP5411237.516HVAC23C5  PDF
IP5415311123HVAC31C5  PDF
IP5418.5381531HVAC38C5  PDF
IP54224618.538HVAC46C5  PDF
IP5430612246HVAC61C5  PDF
Załączniki
No. Document type (Language) File name File size
1. Application manual (English) PDF en1b0389-ge51r1107.pdf 1249 KB
2. Brochure (English) PDF en3b0374-ge51r1007.pdf 1148 KB
3. Engineering Manual (English) PDF en2b0338-ge51r0907.pdf 2580 KB
4. Installation/startup instruction (Multilingual) PDF mu1b0358-ge51r0406.pdf 285 KB
5. Operator manual (English) PDF en1b0388-ge51r1107.pdf 4474 KB
6. Specification sheet (English) PDF en0b0619-ge51r1107.pdf 1162 KB